get
https://dev.signals.actimi.health/api/patient//settings
{} when none were written.
Signals stores settings as given and reads it only through the triggers it holds (triggers, the home's and the resident's own): what each other key means is theirs, so the object is checked for shape and size only. The default pack reads bands — per code { low?, high? }, { mode: 'baseline', pct, low?, high? } (outside either band fires; a patient's own baseline band with no sides of its own is judged alone) or "NO_THRESHOLD" — and outOfBed: { limitSeconds, enabled?, window?: { start: 'HH:MM', end: 'HH:MM', timeZone } }. A patient's own key wins over the org's; extra keys are ignored. See tech/RULES-ENGINE.md.
Recent Requests
Log in to see full request history
| Time | Status | User Agent | |
|---|---|---|---|
Retrieving recent requests… | |||